Thanks Thanks:  0
Likes Likes:  0
Results 1 to 2 of 2

Thread: Bizhub 500

  1. #1
    Junior Member
    Join Date
    Aug 2005
    Posts
    17
    Post Thanks / Like

    Iím working on a Bizhub 500 (B&W)
    Is just to throw a C2403 toner home position cleaned.. Ö
    But now is throwing a c2803
    Went into the counter area and look like this code 3 different options. The count abnormality #3 is the one showing the codes
    Does anyone know what this is referring to?
    According to the manual is referring to a TRC problemÖ. (Cleaned it) do I have to change developer?



  2. #2
    Member
    Join Date
    Dec 2006
    Location
    Lincolnshire UK
    Posts
    63
    Post Thanks / Like
    CODE C-2403 CAN OCCUR AFTER THE CUSTOMER REPLACES THE TONER BOTTLE.
    THIS CAN BE CAUSED BY THE BOTTLE INCORECTLY INSERTED IN THE WRONG POSITION.
    THIS CAN BE RESOLVED BY THE FITTING OF THE NEWLY ESTABLISHED TONER SUPPLY BLOCK. PART NUMBER 50GAP40000.
    There is also a new guide plate.
    [Supply guide plate/lower assembly 50GAR70100]
    Temp repair is to cut off the two square lugs that stick out at the rear of the toner bottle tray.
    Hope this helps.


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •